- APV solar charger is a combination of APC inverter and solar charger. The APV pure sine wave inverter not only makes your solar system simple in wiring, but also has all the unique features from the inverter and solar charger.
Features of APV Pure Sine Wave Inverter, Solar Charger
1. APV pure sine wave inverter adopts low quiescent current, and power saver mode to reduce power consumption to 10W(3s sensing cycle)/3W(30s sensing cycle) *. It can extract max. power from various batteries with different protections.
2. High overload ability of our APV charger is up to 300% rated power(20 sec.), and low voltage trip 9.5V/10V or 10V/10.5V is selectable.
3. Our APV solar charger can achieve reverse current protection and battery temperature compensation, with the high efficiency MPPT function(97%). Auto input DC voltage can be detected between 12V/24V.
4. Our APV pure sine wave inverter supports 3-step intelligent battery charging, and equips with 8 preset battery type selector for totally flat batteries. Its powerful charge rate up to 90Amp**. In addition, PFC(power factor correction) is adopted for charger, which has less power consumption than conventional units
5. LCD status display, USB communication port, battery/AC priority switch are available for our APV pure sine wave inverter, it also has 17 alarms/warnings for easier operation and trouble-shooting, and ability to switch the unit on/off. In addition, select/deselect power saver mode can be used too.
Note:*For 1KW one. **For some models.
6. The APV solar charger has 15s delay before transfer when AC resumes, and the function of overload protection when it equips with generator. Also, it allows start up and through power with depleted batteries.
7. 10ms typical transfer time between battery and AC, which guarantees power continuity of APV pure sine wave inverter. Its input AC voltage is selectable (184-253V or 154-253V) for different kinds of loads. - Technical Parameters of APV Pure Sine Wave Inverter, Solar Charger
Electrical Specifications Model APV 1000W APV 2000W APV 3000W APV 4000W APV 5000W APV 6000W Output (Inverter Mode) Continuous Output Power 1000W 2000W 3000W 4000W 5000W 6000W Surge Rating 3000W 6000W 9000W 12000W 15000W 18000W Output Waveform Pure sine wave/same as input(bypass mode) Nominal Efficiency >88%(peak) Line Mode Efficiency >95% Power Factor 0.9-1.0 Nominal Output
Voltage rms120/230VAC Output Voltage Regulation ±10% rms Output Frequency 50Hz ± 0.3Hz/60Hz ± 0.3Hz Short Circuit Protection Yes( 10s after fault ) Typical Line Stansfer Time 10ms(max.) THD <3% DC Input Nominal Input Voltage 12V 24V 48V Minimum Start Voltage 10V 20V 40V Low Battery Alarm 10.5V 21V 42V Low Battery Trip 10V 20V 40V High Voltage Alarm 16V 32V 64V Low Battery Voltage Recover 13V 26V 52V Idle Consumption-
Search Mode< 25W when power saver on AC Charger Input Voltage Range 95-127VAC 194-243VAC 164-243VAC(W) Output Voltage Depends on battery type Max Charge Rate 35A / 70A Battery Initial Voltage for Start Up 0-15.7V for 12V( *2 for 24V, *4 for 48V) Over Charge Protection Shutdown 15.7V for 12V (*2 for 24V, *4 for 48V) Charger curve(4 stage constant current), battery types 4 step digital controlled progressive charge Battery type Fast V, float V ( *2 for 24v, *4 for 48v) Gel U.S.A 14 13.7 A.G.M 1 14.1 13.4 A.G.M 2 14.6 13.7 Sealed Lead Acid 14.4 13.6 Gel Euro 14.4 13.8 Open Lead Acid 14.8 13.3 Calcium 15.1 13.6 De-sulphation 15.5 for 4hrs Remote Control Yes. Optional Bypass & Protection Input Voltage Waveform Sine wave (grid or generator) Nominal Voltage 120VAC 230VAC Low Voltage Trip 90V±4% 184V/154V±4% Low Voltage Re-engage 100V±4% 194V/164V±4% High Voltage Trip 140V±4% 253V±4% High Voltage Re-engage 135V±4% 243V±4% Max. Input AC Voltage 150VAC 270VAC Nominal Input Frequency 50Hz or 60Hz (auto detect) Low Freq Trip 47Hz± 0.3Hz for 50Hz, 57Hz± 0.3Hz for 60Hz Low Freq Re-engage 48Hz± 0.3Hz for 50Hz, 58Hz± 0.3Hz for 60Hz High Freq Trip 55Hz± 0.3Hz for 50Hz, 65Hz± 0.3Hz for 60Hz High Freq Re-engage 54Hz± 0.3Hz for 50Hz, 64Hz± 0.3Hz for 60Hz Overload Protection Circuit breaker Short Circuit Protection Circuit breaker Transfer Switch Rating 30amp 40amp Bypass Without Battery Connected Yes Max. Bypass Current 30amp 40amp Bypass Over Load Current 35amp: alarm 45amp: alarm Solar Charger Rated Voltage 12V 24V Rated Charge Current 40A Rated Output Current 15A Self Consumption < 10mA(at idle) Bulk Charge 14.5V(default) 29.0V(default) Floating Charge① 13.5V(default) 27.0V(default) Equalization Charge① 14.0V(default) 28.0V(default) Over Charge Disconnection 14.8V 29.6V Over Charge Recovery 13.6V 27.2V Over Discharge Disconnection① 10.8 V(default) 21.6V(default) Over Discharge Reconnection 12.3V 24.6V Temperature
Compensation①-13.2mV/℃ -26.4mV/℃ Ambient Temperature 0-40℃(full load) 40-60℃(derating) Mechanical Specifications Mounting Wall mount Inverter Dimensions(L*W*H) 598*218*179mm 470*190*340mm Inverter Weight 21KG 23KG 27KG 38KG 48KG 48KG Shipping Dimensions(L*W*H) 740*315*300mm 530*240*390mm Shipping Weight 23KG 25KG 29KG 40KG 50KG 50KG Display Status LEDs / status LEDs+LCD Standard Warranty 1 year APV Series Inverter&Solar Charger
Electrical Specvifications Model APV
1000WAPV
1500WAPV
2000WAPV
3000WAPV
4000WAPV
5000WAPV
6000WOutput (Inverter mode) Continuous Output Power 1000W 1500W 2000W 3000W 4000W 5000W 6000W Surge Rating 3000W 4500W 6000W 9000W 12000W 15000W 18000W Output Waveform Pure Sine wave/Same as input(Bypass mode) Nominal Efficiency >88%(Peak) Line Mode Efficiency >95% Power Factor 0.9-1.0 Nominal Output
Voltage rms100-110-120Vac / 220-230-240Vac Output Voltage Regulation ±10% RMS Output Frequency 50Hz ± 0.3Hz/60Hz ± 0.3Hz Short Circuit Protection Yes( 1sec after fault ) Typical Line Stansfer Time 10ms(MAX) THD <10% DC Input Nominal Input Voltage 12.0Vdc ( *2 for 24Vdc, *4 for 48Vdc) Minimum Start Voltage 10.0Vdc Low Battery Alarm 10.5Vdc / 11.0Vdc Low Battery Trip 10.0Vdc / 10.5Vdc High Voltage Alarm 16.0Vdc Low Batteryvoltage
recover15.5Vdc Idle Consumption-
Search Mode< 25 W when Power Saver On AC Charger Input Voltage Range Wide: 90~135VAC / 164~243VAC;
Narraw: 100~135VAC / 194~243VAC;Output Voltage Depends on battery type Max Charge Rate 35A / 70-90A Max (Charger Current Control) Battery InitialVoltagefor
Start UpCircuit breaker Over ChargeProtection
Shutdown15.7V for 12V( *2 for 24Vdc, *4 for 48Vdc) Charger curve
(4 stage constant current)
4 step digital controlled progressive chargeBattery types ( *2 for 24Vdc, *4 for 48Vdc) Battery type Fast V Float V( *2 for 24Vdc, *4 for 48Vdc) Gel U.S.A 14.0 13.7 A.G.M 1 14.1 13.4 A.G.M 2 14.6 13.7 Sealed Lead Acid 14.4 13.6 Gel Euro 14.4 13.8 Open Lead Acid 14.8 13.3 Calcium 15.1 13.6 De-sulphation 15.5 for 4hrs Remote Control Yes. Optional Bypass & Protection Input Voltage Waveform Sine wave (Grid or Generator) Nominal Voltage 120VAC / 230VAC Low Voltage Trip 90V±4%/184V/154V±4% Low Voltage re engage 100V±4%/194V/164V±4% High Voltage Trip 140V±4%/ 253V±4% High Voltage re engage 135V±4%/243V±4% Max Input AC Voltage 150VAC/270VAC Nominal Input Frequency 50Hz or 60Hz (Auto detect) Low freq trip 47Hz± 0.3Hz for 50Hz, 57Hz± 0.3Hz for 60Hz Low freq re engage 48Hz± 0.3Hz for 50Hz, 58Hz± 0.3Hz for 60Hz High freq trip 55Hz± 0.3Hz for 50Hz, 65Hz± 0.3Hz for 60Hz High freq re engage 54Hz± 0.3Hz for 50Hz, 64Hz± 0.3Hz for 60Hz Overload protection Circuit breaker Short circuit protection Circuit breaker Transfer switch rating 30amp 40amp Max bypass current 30amp 40amp Bypass over load current 35amp: Alarm 45amp: Alarm Solar Charger Rated Voltage 12V/24V/48V Rated Charge Current 40A/60A Rated Output Current 15A Self Consumption < 10mA Bulk Charge 14.5V(default) ( *2 for 24Vdc, *4 for 48Vdc) Floating Charge 13.5V(default) Equalization Charge 14.0V(default) Over Charge
Disconnection14.8V Over Charge Recovery 13.6V Over Discharge
Disconnection10.8 V(default) Over Discharge
Reconnection12.3V Temperature
Compensation– 13.2mV/℃ Ambient Temperature 0-40℃(full load) 40-60℃(derating) Mechanical Specifications Mounting Wall mount Inverter Dimensions
(L*W*H)598*218*179mm 470*190*340mm Inverter Weight 21KG 22kg 23KG 27KG 38KG 48KG 48KG Shipping Dimensions
(L*W*H)740*315*300mm 530*240*390mm Shipping Weight 23KG 24kg 25KG 29KG 40KG 50KG 50KG Display Status LEDs / Status LEDs+LCD Standard Warranty 1 Year
PSW7 APC APS APV APP HP Series Inverter&Charger Selection Guide

YueQing YIYEN Electric Technology Co., Ltd is a professional manufacturer on Voltage Stabilizer, Inverter and UPS.
- Located in Liushi, WenZhou, which is a capital of electrical in China;
- We have been in Power industry for more than 7 years;
- Good quality ,Reasonable price;
- Accepted Retail if we have product in stock;
- Accepted Wholesale,Brand Agents,OEM,ODM and Can be Customized;
- Accepted Payment Type: T/T, PayPal, Western Union;
